Methodology: Part III
The following experiment illustrated to what extent water
elutes cyanide ions. Two 0.5-gram plaster samples,
previously subjected to a fumigation with hydrogen cyanide
(after the determination of cyanide combinations in them)
were placed on filter paper in glass funnels and either of
them was flushed with 1l of clean, deionized distilled
water. The results of the test are presented in
Table VII.